IF 조합 측정치를 사용하는 단독 정밀 측위 오차해석An Error Analysis of precise Point Positioning using Ionosphere Free Combination Measurement
- Other Titles
- An Error Analysis of precise Point Positioning using Ionosphere Free Combination Measurement
- Authors
- 박슬기; 조득재; 신영철; 박찬식
- Issue Date
- 28-9월-2012
- Publisher
- 제어로봇시스템
- Keywords
- error analysis; PPP; ionosphere free combination; ionosphere difference
- Citation
- 제어로봇시스템, v.18, no.9, pp 871 - 877
- Pages
- 7
- Journal Title
- 제어로봇시스템
- Volume
- 18
- Number
- 9
- Start Page
- 871
- End Page
- 877
- URI
- https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/8156
- Abstract
- An error analysis of PPP(Precise Point Positioning) using IF(Ionosphere Free) combination is
given. It is shown that the performance of the ordinary model with positions, clock bias, integer
ambiguities and ionosphere delay as unknowns is equivalent to that of an ionosphere difference
combination where ionosphere delay is cancelled out. Furthermore, it is shown that IF combination
is an ionosphere difference combination but not unique. It is also proved that all difference
models show same performances. The error analysis evaluated with a hardware simulator and real
measurements show that the ionosphere delay is effectively eliminated by IF combination or
equivalently by the ionosphere difference combination. However, if bias errors such as
troposphere, clock bias or multipath are included in the measurements, the performance of the IF
combination is degraded because the bias errors are amplified by the ionosphere difference
operation.is equivalent to that of an ionosphere difference
combination where ionosphere delay is cancelled out. Furthermore, it is shown that IF combination
is an ionosphere difference combination but not unique. It is also proved that all difference
models show same performances. The error analysis evaluated with a hardware simulator and real
measurements show that the ionosphere delay is effectively eliminated by IF combination or
equivalently by the ionosphere difference combination. However, if bias errors such as
troposphere, clock bias or multipath are included in the measurements, the performance of the IF
combination is degraded because the bias errors are amplified by the ionosphere difference
operation.