IF 조합 측정치를 사용하는 단독 정밀 측위 오차해석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박슬기 | - |
dc.contributor.author | 조득재 | - |
dc.contributor.author | 신영철 | - |
dc.contributor.author | 박찬식 | - |
dc.date.accessioned | 2023-12-22T08:00:31Z | - |
dc.date.available | 2023-12-22T08:00:31Z | - |
dc.date.issued | 2012-09-28 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/8156 | - |
dc.description.abstract | An error analysis of PPP(Precise Point Positioning) using IF(Ionosphere Free) combination is given. It is shown that the performance of the ordinary model with positions, clock bias, integer ambiguities and ionosphere delay as unknowns is equivalent to that of an ionosphere difference combination where ionosphere delay is cancelled out. Furthermore, it is shown that IF combination is an ionosphere difference combination but not unique. It is also proved that all difference models show same performances. The error analysis evaluated with a hardware simulator and real measurements show that the ionosphere delay is effectively eliminated by IF combination or equivalently by the ionosphere difference combination. However, if bias errors such as troposphere, clock bias or multipath are included in the measurements, the performance of the IF combination is degraded because the bias errors are amplified by the ionosphere difference operation.is equivalent to that of an ionosphere difference combination where ionosphere delay is cancelled out. Furthermore, it is shown that IF combination is an ionosphere difference combination but not unique. It is also proved that all difference models show same performances. The error analysis evaluated with a hardware simulator and real measurements show that the ionosphere delay is effectively eliminated by IF combination or equivalently by the ionosphere difference combination. However, if bias errors such as troposphere, clock bias or multipath are included in the measurements, the performance of the IF combination is degraded because the bias errors are amplified by the ionosphere difference operation. | - |
dc.format.extent | 7 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 제어로봇시스템 | - |
dc.title | IF 조합 측정치를 사용하는 단독 정밀 측위 오차해석 | - |
dc.title.alternative | An Error Analysis of precise Point Positioning using Ionosphere Free Combination Measurement | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 제어로봇시스템, v.18, no.9, pp 871 - 877 | - |
dc.citation.title | 제어로봇시스템 | - |
dc.citation.volume | 18 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 871 | - |
dc.citation.endPage | 877 | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | error analysis | - |
dc.subject.keywordAuthor | PPP | - |
dc.subject.keywordAuthor | ionosphere free combination | - |
dc.subject.keywordAuthor | ionosphere difference | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.