Performance evaluation of Ocean Thermal Energy Conversion(OTEC) stabilization based on risk analysis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 임승택 | - |
dc.contributor.author | 이호생 | - |
dc.contributor.author | 윤지원 | - |
dc.contributor.author | 김현주 | - |
dc.date.accessioned | 2023-12-22T10:30:46Z | - |
dc.date.available | 2023-12-22T10:30:46Z | - |
dc.date.issued | 2023-02 | - |
dc.identifier.issn | 2234-7925 | - |
dc.identifier.issn | 2765-4796 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/9695 | - |
dc.description.abstract | Research and development of OTEC, a renewable energy power generation facility using seawater heat, is underway worldwide, and the development of a demonstration plant has been promoted in Korea. However, for the commercialization of OTEC, alternative operating scenarios must be derived for various environmental changes. Therefore, preemptively identifying the risk factors of the system, analyzing the effects of the system, establishing control items, and verifying the results through simulation are necessary. This study proposes a method to minimize risk factors along with a risk analysis of the risk factors of MW-scale OTEC, such as refrigerant leakage and riser loss. The selected OTEC was designed for 1070 kW-class facilities, and 36.6% of the total power is consumed by seawater pumps and refrigerant pumps. The refrigerant was assumed to be leaked owing to the opening of the valve to the top of the refrigerant tank, and the performance change was confirmed by assuming that the refrigerant leaked at an average rate of approximately 21 kg/s. In addition, the riser loss assumed a rapidly changing deep water temperature, and the system was operated to stop when the deep water temperature increased up to 18°C. | - |
dc.format.extent | 11 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 한국마린엔지니어링학회 | - |
dc.title | Performance evaluation of Ocean Thermal Energy Conversion(OTEC) stabilization based on risk analysis | - |
dc.title.alternative | Performance evaluation of Ocean Thermal Energy Conversion(OTEC) stabilization based on risk analysis | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.5916/jamet.2023.47.1.1 | - |
dc.identifier.bibliographicCitation | 한국마린엔지니어링학회지, v.47, no.1, pp 1 - 11 | - |
dc.citation.title | 한국마린엔지니어링학회지 | - |
dc.citation.volume | 47 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 11 | - |
dc.identifier.kciid | ART002936521 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Hazard analysis | - |
dc.subject.keywordAuthor | Ocean thermal energy conversion | - |
dc.subject.keywordAuthor | Subsystem risk analysis | - |
dc.subject.keywordAuthor | Refrigerant leakage | - |
dc.subject.keywordAuthor | Riser loss | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.