Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

해양플랜트의 안전 무결도 수준 적용을 위한 표준 분석Standard Analysis for Application of Safety Integrity Level in Offshore Plant

Other Titles
Standard Analysis for Application of Safety Integrity Level in Offshore Plant
Authors
박상현노현정조수길강관구
Issue Date
12월-2017
Publisher
한국해양과학기술원 부설 선박해양플랜트연구소
Keywords
IEC 61508; IEC 61511; Safety Integrity Level; Safety Instrumented System; Safety Instrumented Function
Citation
선박해양기술, v.1, no.58, pp 81 - 88
Pages
8
Journal Title
선박해양기술
Volume
1
Number
58
Start Page
81
End Page
88
URI
https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/8285
Abstract
The importance of SIL(Safety Integrity Level)-based SIS(Safety Instrumented System) design, which can secure the required functional safety and prevent dangerous accidents when the failure of system occur, has been attracting much attention in recent years. In order to ensure the risk within the acceptable levels through the SIL-based SIS design, the requirements suggested in IEC 61508 and IEC 61511 standards should be followed. Therefore, in this study, the IEC 61508 and IEC 61511 standards are analyzed to establish a procedure to correctly perform SIL on an offshore plant. The safety lifecycle suggested in the above standards only describes the stages considered to perform the SIL-based SIL design in this study.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Noh, Hyonjeong photo

Noh, Hyonjeong
친환경해양개발연구본부 (해양플랜트산업지원센터)
Read more

Altmetrics

Total Views & Downloads

BROWSE