SENSITIVITY OF THERMAL FACTORS TO PMV/PPD IN CABINS OF MARITIME PATROL VESSEL
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 장미숙 | - |
dc.contributor.author | 고창두 | - |
dc.contributor.author | 문일성 | - |
dc.contributor.author | 김상현 | - |
dc.date.accessioned | 2021-12-08T23:40:59Z | - |
dc.date.available | 2021-12-08T23:40:59Z | - |
dc.date.issued | 20050907 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/6897 | - |
dc.description.abstract | This paper focused on the evaluation of thermal comfort in 1,000 ton patrol vessel using PMV (predicted mean vote) and PPD (predicted percentage of dissatisfied). Environmental factors, room temperature and relative humidity, was measured in various cabins. Human factors, clothing and activity, in the vessel were modified using inland indoor characteristics and investigated by the survey research for maritime polices. Most crews were satisfied with thermal environment in wheel house and accommodation 1. However, in galley, engine control room, engine room and auxiliary machine room, the number of crews who is not satisfied with the environment was increased remarkably. The most sensitive factor to PMV is room temperature in wheel house and accommodation where crews do a light work and metabolic rate in galley, engine control room and etc. where they do a hard work. Therefore, it is necessary to operate a HVAC (heating, ventilation and cooling) system controlled by proper thermal factors in each cabin. This operating system would be one of the economic and comfortable design techniques that the whole cabins are maintainable the ideal thermal comfort conditions. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.title | SENSITIVITY OF THERMAL FACTORS TO PMV/PPD IN CABINS OF MARITIME PATROL VESSEL | - |
dc.title.alternative | SENSITIVITY OF THERMAL FACTORS TO PMV/PPD IN CABINS OF MARITIME PATROL VESSEL | - |
dc.type | Conference | - |
dc.citation.title | Indoor Air 2005 | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 260 | - |
dc.citation.endPage | 265 | - |
dc.citation.conferenceName | Indoor Air 2005 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.