Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance Characteristics of 20kW OTEC Pilot Plant in KOREA

Full metadata record
DC Field Value Language
dc.contributor.author이호생-
dc.contributor.author정영권-
dc.contributor.author김영석-
dc.contributor.author임승택-
dc.contributor.author김현주-
dc.date.accessioned2021-12-08T14:40:29Z-
dc.date.available2021-12-08T14:40:29Z-
dc.date.issued20150626-
dc.identifier.urihttps://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/4167-
dc.description.abstractTo experiment 20kW OTEC, the closed-cycle type of OTEC (Ocean Thermal Energy Conversion) was designed and manufactured. R32 (Difluoromethane, CH2F2) was used as the working fluid and a temperature of heat source and heat sink is 26oC, 5oC, respectively. The semi-welded type heat exchanger is applied for the evaporator and condenser and the cycle was designed for the gross power of 20kW. In the plate arrangement of the semi-welded type heat exchanger, one channel for working fluid is welded, and another channel for seawater is sealed by gasket. In this paper, various performance evaluation and experiment was carried out as constructing subminiature pilot plant of the OTEC and compared with the results of cycle analysis. In results, gross power of the turbine shows 20.1kW and cycle efficiency is 1.91% when heat source and heat sink is 26oC, 5oC. For the variation of temperature difference between the heat source and heat sink, when the temperature difference was 21oC, the gross power increased by about 33.3% from that when the temperature difference was 19oC.respectively. The semi-welded type heat exchanger is applied for the evaporator and condenser and the cycle was designed for the gross power of 20kW. In the plate arrangement of the semi-welded type heat exchanger, one channel for working fluid is welded, and another channel for seawater is sealed by gasket. In this paper, various performance evaluation and experiment was carried out as constructing subminiature pilot plant of the OTEC and compared with the results of cycle analysis. In results, gross power of the turbine shows 20.1kW and cycle efficiency is 1.91% when heat source and heat sink is 26oC, 5oC. For the variation of temperature difference between the heat source and heat sink, when the temperature difference was 21oC, the gross power increased by about 33.3% from that when the temperature difference was 19oC.-
dc.language영어-
dc.language.isoENG-
dc.titlePerformance Characteristics of 20kW OTEC Pilot Plant in KOREA-
dc.title.alternativePerformance Characteristics of 20kW OTEC Pilot Plant in KOREA-
dc.typeConference-
dc.citation.titleISOPE 2015-
dc.citation.volume1-
dc.citation.number1-
dc.citation.startPage1088-
dc.citation.endPage1093-
dc.citation.conferenceNameISOPE 2015-
Files in This Item
There are no files associated with this item.
Appears in
Collections
해양에너지연구본부 > Seawater Energy Plant Research Center(SEPRC) > 2. Conference Papers
친환경해양개발연구본부 > 해수에너지연구센터 > Conference Papers

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyeon Ju photo

Kim, Hyeon Ju
친환경해양개발연구본부 (해수에너지연구센터)
Read more

Altmetrics

Total Views & Downloads

BROWSE