Performance Characteristics of 20kW OTEC Pilot Plant in KOREA
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이호생 | - |
dc.contributor.author | 정영권 | - |
dc.contributor.author | 김영석 | - |
dc.contributor.author | 임승택 | - |
dc.contributor.author | 김현주 | - |
dc.date.accessioned | 2021-12-08T14:40:29Z | - |
dc.date.available | 2021-12-08T14:40:29Z | - |
dc.date.issued | 20150626 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/4167 | - |
dc.description.abstract | To experiment 20kW OTEC, the closed-cycle type of OTEC (Ocean Thermal Energy Conversion) was designed and manufactured. R32 (Difluoromethane, CH2F2) was used as the working fluid and a temperature of heat source and heat sink is 26oC, 5oC, respectively. The semi-welded type heat exchanger is applied for the evaporator and condenser and the cycle was designed for the gross power of 20kW. In the plate arrangement of the semi-welded type heat exchanger, one channel for working fluid is welded, and another channel for seawater is sealed by gasket. In this paper, various performance evaluation and experiment was carried out as constructing subminiature pilot plant of the OTEC and compared with the results of cycle analysis. In results, gross power of the turbine shows 20.1kW and cycle efficiency is 1.91% when heat source and heat sink is 26oC, 5oC. For the variation of temperature difference between the heat source and heat sink, when the temperature difference was 21oC, the gross power increased by about 33.3% from that when the temperature difference was 19oC.respectively. The semi-welded type heat exchanger is applied for the evaporator and condenser and the cycle was designed for the gross power of 20kW. In the plate arrangement of the semi-welded type heat exchanger, one channel for working fluid is welded, and another channel for seawater is sealed by gasket. In this paper, various performance evaluation and experiment was carried out as constructing subminiature pilot plant of the OTEC and compared with the results of cycle analysis. In results, gross power of the turbine shows 20.1kW and cycle efficiency is 1.91% when heat source and heat sink is 26oC, 5oC. For the variation of temperature difference between the heat source and heat sink, when the temperature difference was 21oC, the gross power increased by about 33.3% from that when the temperature difference was 19oC. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.title | Performance Characteristics of 20kW OTEC Pilot Plant in KOREA | - |
dc.title.alternative | Performance Characteristics of 20kW OTEC Pilot Plant in KOREA | - |
dc.type | Conference | - |
dc.citation.title | ISOPE 2015 | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1088 | - |
dc.citation.endPage | 1093 | - |
dc.citation.conferenceName | ISOPE 2015 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.