Comparison of OTEC cycle by Various Refrigerant
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 임승택 | - |
dc.contributor.author | 이호생 | - |
dc.contributor.author | 이승원 | - |
dc.contributor.author | 김현주 | - |
dc.date.accessioned | 2021-12-08T14:40:23Z | - |
dc.date.available | 2021-12-08T14:40:23Z | - |
dc.date.issued | 20150902 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/4140 | - |
dc.description.abstract | OTEC is using a phase change of the refrigerant. It is converted to the low-temperature thermal energy into kinetic energy and kinetic energy is converted into electrical energy. Thus, depending on use of any refrigerant, there occurs a difference between the output and the system efficiency. At present, the OTEC application or kind of the refrigerant in the study as an AMMONIA, R22, R32, R134a and the like, and the application can vary according to the characteristics and research of the system. In this paper, refrigerant of a heat source used in existing AMMONIA, R32, R22, R134a were conducted using the system performance changes in accordance with various heat sink temperature. System was designed to basic model closed-cycle the program used in the design was used HYSYS program. That temperature was applied to the surface water temperature of the Pacific Ocean 30 ℃, changes in heat sink temperature 5 ℃, 8 ℃, 10 ℃, was applied to 12 ℃.ference between the output and the system efficiency. At present, the OTEC application or kind of the refrigerant in the study as an AMMONIA, R22, R32, R134a and the like, and the application can vary according to the characteristics and research of the system. In this paper, refrigerant of a heat source used in existing AMMONIA, R32, R22, R134a were conducted using the system performance changes in accordance with various heat sink temperature. System was designed to basic model closed-cycle the program used in the design was used HYSYS program. That temperature was applied to the surface water temperature of the Pacific Ocean 30 ℃, changes in heat sink temperature 5 ℃, 8 ℃, 10 ℃, was applied to 12 ℃. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.title | Comparison of OTEC cycle by Various Refrigerant | - |
dc.title.alternative | Comparison of OTEC cycle by Various Refrigerant | - |
dc.type | Conference | - |
dc.citation.title | 2015 international OTEC symposium | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 26 | - |
dc.citation.endPage | 26 | - |
dc.citation.conferenceName | 2015 international OTEC symposium | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.