dc.description.abstract200kW High temperature ocean thermal energy conversion(HOTEC) was designed and bullit in the end of 2014 which uses unused energy such as waste heat and geothermal heat, etc. as heat source and deep seawater as heat sink. To operate and test for performance of 200kW HOTEC, a closed rankine cycle was designed and fabricated. we chose R245fa as the working fluid and the temperature of the heat source and heat sink were 75℃ and 5℃, respectively. The heat exchanger for evaporator and condenser was manufactured by Titanium and Oxynitride coating(SPCC) plates resisting to sea water corrosion, and the HOTEC cycle was designed for a gross power of 200kW. HOTEC plant was installed in Seawater Utilization Plant Research Center in Gosung-gun, Gangwon-do. For performance test of the 200kW HOTEC plant, the experiment results were compared according to the temperature difference between heat source and heat sink.st for performance of 200kW HOTEC, a closed rankine cycle was designed and fabricated. we chose R245fa as the working fluid and the temperature of the heat source and heat sink were 75℃ and 5℃, respectively. The heat exchanger for evaporator and condenser was manufactured by Titanium and Oxynitride coating(SPCC) plates resisting to sea water corrosion, and the HOTEC cycle was designed for a gross power of 200kW. HOTEC plant was installed in Seawater Utilization Plant Research Center in Gosung-gun, Gangwon-do. For performance test of the 200kW HOTEC plant, the experiment results were compared according to the temperature difference between heat source and heat sink.-
dc.language한국어-
dc.language.isoKOR-
dc.title200kW 고온도차발전플랜트 운전 및 성능실험-
dc.title.alternativeOperation and Test of 200kW HOTEC Plant-
dc.typeConference-
dc.citation.title한국동력기계공학회 추계학술대회-
dc.citation.volume1-
dc.citation.number1-
dc.citation.startPage89-
dc.citation.endPage90-
dc.citation.conferenceName한국동력기계공학회 추계학술대회-
Files in This Item
There are no files associated with this item.
Appears in
Collections
해양에너지연구본부 > Seawater Energy Plant Research Center(SEPRC) > 2. Conference Papers
친환경해양개발연구본부 > 해수에너지연구센터 > Conference Papers

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Seung Taek photo

Lim, Seung Taek
친환경해양개발연구본부 (해수에너지연구센터)
Read more

Altmetrics

Total Views & Downloads

BROWSE