Detailed Information

Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads

Dynamic Simulation of System Performance Change by PID Automatic Control of Ocean Thermal Energy Conversion

Full metadata record
DC Field Value Language
dc.contributor.authorSeungtaek, Lim-
dc.contributor.authorHoseang, Lee-
dc.contributor.authorHyeonju, Kim-
dc.date.accessioned2021-08-03T04:21:37Z-
dc.date.available2021-08-03T04:21:37Z-
dc.date.issued2020-01-
dc.identifier.issn2077-1312-
dc.identifier.issn2077-1312-
dc.identifier.urihttps://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/245-
dc.description.abstractNear infinite seawater thermal energy, which is considered as an alternative to energy shortage, is expected to be available to 98 countries around the world. Currently, a demonstration plant is being built using closed MW class ocean thermal energy conversion (OTEC). In order to stabilize the operation of the OTEC, automation through a PID control is required. To construct the control system, the control logic is constructed, the algorithm is selected, and each control value is derived. In this paper, we established an optimal control system of a closed OTEC, which is to be demonstrated in Kiribati through simulation, to compare the operating characteristics and to build a system that maintains a superheat of 1 degrees C or more according to seawater temperature changes. The conditions applied to the simulation were the surface seawater temperature of 31 degrees C and the deep seawater temperature of 5.5 degrees C, and the changes of turbine output, flow rate, required power, and evaporation pressure of the refrigerant pump were compared as the temperature difference gradually decreased. As a result of comparing the RPM control according to the selected PID control value, it was confirmed that an error rate of 0.01% was shown in the temperature difference condition of 21.5 degrees C. In addition, the average superheat degree decreased as the temperature difference decreased, and after about 6000 s and a temperature decrease to 24 degrees C or less, the average superheat degree was maintained while maintaining the superheat degree of 1.7 degrees C on average.-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI-
dc.titleDynamic Simulation of System Performance Change by PID Automatic Control of Ocean Thermal Energy Conversion-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/jmse8010059-
dc.identifier.scopusid2-s2.0-85084044385-
dc.identifier.wosid000513656700008-
dc.identifier.bibliographicCitationJOURNAL OF MARINE SCIENCE AND ENGINEERING, v.8, no.1-
dc.citation.titleJOURNAL OF MARINE SCIENCE AND ENGINEERING-
dc.citation.volume8-
dc.citation.number1-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaOceanography-
dc.relation.journalWebOfScienceCategoryEngineering, Marine-
dc.relation.journalWebOfScienceCategoryEngineering, Ocean-
dc.relation.journalWebOfScienceCategoryOceanography-
dc.subject.keywordAuthordeep sea water-
dc.subject.keywordAuthorsurface water-
dc.subject.keywordAuthorocean thermal energy conversion-
dc.subject.keywordAuthorclosed cycle-
dc.subject.keywordAuthorproportional-integral-differential controller-
Files in This Item
Appears in
Collections
친환경해양개발연구본부 > 해수에너지연구센터 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Seung Taek photo

Lim, Seung Taek
친환경해양개발연구본부 (해수에너지연구센터)
Read more

Altmetrics

Total Views & Downloads

BROWSE