Risk assessment of solid desiccant dehydration package system using safety integrity level-based safety instrumented system design approach
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Sanghyun | - |
dc.contributor.author | Lee, Tae Hee | - |
dc.contributor.author | Kang, Kwangu | - |
dc.contributor.author | Noh, Hyonjeong | - |
dc.contributor.author | Kim, Hyungwoo | - |
dc.contributor.author | Oh, Jaewon | - |
dc.contributor.author | Kim, Kyong-Hwan | - |
dc.contributor.author | Cho, Su-gil | - |
dc.date.accessioned | 2023-12-22T10:30:34Z | - |
dc.date.available | 2023-12-22T10:30:34Z | - |
dc.date.issued | 2023-08 | - |
dc.identifier.issn | 1066-8527 | - |
dc.identifier.issn | 1547-5913 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/9670 | - |
dc.description.abstract | The dehydration package system plays an important role in the stable process operation and production of high-quality liquefied natural gas by removing water, which is essential for natural gas production. However, as this system operates under various conditions with chemicals, there are threats to safety from potential hazards within the system. Therefore, ensuring system safety can significantly impact the reliable operation of process plants. This study aims to assess the risk of the dehydration package system through the safety integrity level (SIL)-based safety instrumented system (SIS) design approach as suggested in the International Electrotechnical Commission (IEC) 61,508/61511 standards. Fourteen major hazards requiring recommendations were identified for improving safety through the hazard and operability study (HAZOP). The three major hazards were valve malfunction and gas heater/cooler control failure. Twenty-one safety instrumented functions (SIFs) in all study nodes were suggested as recommendations to improve safety. Using layers of protection analysis (LOPA), the SIL allocation of the 21 SIFs was performed reasonably with process risks and safeguards. The PDS method was adopted for SIS design and verification, with SIL analysis performed for all the SISs. The results showed that SISs of the dehydration package system satisfied the required SILs. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | WILEY | - |
dc.title | Risk assessment of solid desiccant dehydration package system using safety integrity level-based safety instrumented system design approach | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1002/prs.12518 | - |
dc.identifier.scopusid | 2-s2.0-85166659526 | - |
dc.identifier.wosid | 001042086000001 | - |
dc.identifier.bibliographicCitation | PROCESS SAFETY PROGRESS | - |
dc.citation.title | PROCESS SAFETY PROGRESS | - |
dc.type.docType | Article; Early Access | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Chemical | - |
dc.subject.keywordPlus | MARKOV-CHAINS | - |
dc.subject.keywordAuthor | risk assessment | - |
dc.subject.keywordAuthor | safety instrumented system | - |
dc.subject.keywordAuthor | safety integrity level | - |
dc.subject.keywordAuthor | SIL-based SIS design | - |
dc.subject.keywordAuthor | solid desiccant dehydration package system | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.