Evaluation of the two phase pressure drop during the CO2-N2 mixture pipeline transport

Full metadata record
DC Field Value Language
dc.contributor.authorCho, M.-I.-
dc.contributor.authorHuh, C.-
dc.contributor.authorKang, S.-G.-
dc.contributor.authorBaek, J.-H.-
dc.date.accessioned2021-08-03T04:47:08Z-
dc.date.available2021-08-03T04:47:08Z-
dc.date.issued2014-
dc.identifier.issn1876-6102-
dc.identifier.urihttps://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/926-
dc.description.abstractCaptured CO2 mixture for sequestration purpose can contain impurities such as N2, NOx, SOx, O2, H2O, H2, H2S, Ar. Such impurities affect the critical temperature and pressure, density, viscosity, saturation temperature-pressure line, etc. Among the impurities, N2 can affect the CO2 stream properties largely cause of the low boiling point and high specific volume, so a small ratio of N2 inflow might change the flow pattern of CO2 stream from single phase to two phase flow. To understand the flow behavior of two phase CO2 stream with N2 impurity, experimental investigations should be carried out and compared with existing correlation to figure out the accuracy of correlations. In this study we designed and installed an experimental facility to simulate the two phase flow behavior of CO2-N2 mixture during the pipeline transportation. The test section is composed of a single 6 meter STS304 tube with inner diameter of 3.8608mm with inlet absolute pressure transmitter and inlet-outlet differential pressure transmitter. Test condition was 21 and 85 bar with varying N2 impurity ratio. In this study the two-phase flow pressure drop data of CO2-N2 mixture flow are compared with correlations of Lockhart-Martinelli, Zhang et al, and Misima & Hibiki. Among three candidate correlations Mishima & Hibiki correlation showed the best accuracy. All of three correlations showed rather low accuracy, but it might be from the reason that the correlations were originally designed to estimate water-vapor two-phase flow pressure drop. The result also shows the need to investigate further visualization and flow pattern identification. ? 2014 The Authors Published by Elsevier Ltd.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier Ltd-
dc.titleEvaluation of the two phase pressure drop during the CO2-N2 mixture pipeline transport-
dc.typeArticle-
dc.identifier.doi10.1016/j.egypro.2014.11.293-
dc.identifier.scopusid2-s2.0-84922928229-
dc.identifier.bibliographicCitationEnergy Procedia, v.63, pp 2710 - 2714-
dc.citation.titleEnergy Procedia-
dc.citation.volume63-
dc.citation.startPage2710-
dc.citation.endPage2714-
dc.type.docTypeConference Paper-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorCarbon dioxide capture and storage(ccs)-
dc.subject.keywordAuthorCO2 transport-
dc.subject.keywordAuthorN2 impurity-
dc.subject.keywordAuthorPipeline transport-
dc.subject.keywordAuthorSteady flow-
dc.subject.keywordAuthorTwo-phase flow-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Seong-Gil photo

Kang, Seong-Gil
연구전략본부 (국제해사기술센터)
Read more

Altmetrics

Total Views & Downloads

BROWSE