Improved analytical modeling of axial flux machine with a double-sided permanent magnet rotor and slotless stator based on an analytical method
- Authors
- Sung, S.-Y.; Jeong, J.-H.; Park, Y.-S.; Choi, J.-Y.; Jang, S.-M.
- Issue Date
- 2012
- Keywords
- Equivalent circuit; Generator design; Magnetic field solution; Power analysis; Quasi-3D
- Citation
- IEEE Transactions on Magnetics, v.48, no.11, pp 2945 - 2948
- Pages
- 4
- Journal Title
- IEEE Transactions on Magnetics
- Volume
- 48
- Number
- 11
- Start Page
- 2945
- End Page
- 2948
- URI
- https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/8798
- DOI
- 10.1109/TMAG.2012.2203112
- ISSN
- 0018-9464
1941-0069
- Abstract
- This paper presents the results of an experimental verification and electromagnetic field analysis for an axial flux permanent magnet (PM) synchronous generator (AFPMSG) with a double-sided PM rotor and slotless stator windings based on analytical field computation to offer improved analytical modeling method. An analytical approach to analyze the magnetic field distribution and estimate the equivalent circuit parameters is presented that dramatically reduces analysis time while maintaining high reliability. Since the flux leakage phenomenon is dominant in the inner and outer radii of this type of AFPMSG, it is specifically considered. In addition, an actual device was fabricated on the basis of one of the analysis models, and used to experimentally verify all of the analysis results. ? 2012 IEEE.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 친환경해양개발연구본부 > 친환경연료추진연구센터 > Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.