Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of hydrostatic pressure test and finite element analysis results of cylindrical pressure vessel with various thicknesses

Authors
Kim, J.-M.Choi, H.-J.Lee, S.-G.Joung, T.-H.Lee, J.-H.
Issue Date
2019
Publisher
Institute of Electrical and Electronics Engineers Inc.
Keywords
Deep-sea pressure vessel; Finite element analysis (FEA); Hydrostatic pressure test; Hyperbaric chamber
Citation
OCEANS 2019 - Marseille, OCEANS Marseille 2019, v.2019-June
Journal Title
OCEANS 2019 - Marseille, OCEANS Marseille 2019
Volume
2019-June
URI
https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/8358
DOI
10.1109/OCEANSE.2019.8867263
ISSN
0000-0000
Abstract
The collapse behavior of offshore apparatus under external pressure is a primary concern for design criteria of structural integrity. Finite element analysis of the collapse behavior for various thick and thin-walled pressure vessels under external hydrostatic pressure were performed. The cylinder and both ends are connected by welding or bolting, and the ultimate collapse points are usually near the connected part while initial plastic deformation occurs in the form of buckling in the cylindrical part. Therefore, in order to evaluate the structural safety of the pressure vessel, it is necessary to consider the failure of the connection part, together with the cylindrical part in the middle and both ends, where the initial large deflection occurs. Local structural analysis for the pressure vessel considering the bolted part was carried out as well as global buckling analysis. That is, aluminium alloy and stainless steel pressure vessel models were designed for operating under high pressure equivalent to the water depth up to 2000m and 1000m, respectively. Pressure vessel design procedure was performed by using empirical formulae and eigenvalue analysis by FEM code. The results were verified and investigated by pressure tests in the hyperbaric chamber of KRISO. It was found that all the estimated results by the empirical formula and FEA are overestimated when the results are compared to the pressure test results in the pressure chamber. ? 2019 IEEE.
Files in This Item
There are no files associated with this item.
Appears in
Collections
해양공공디지털연구본부 > 해사안전·환경연구센터 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hyuek Jin photo

Choi, Hyuek Jin
해양공공디지털연구본부 (해사안전·환경연구센터)
Read more

Altmetrics

Total Views & Downloads

BROWSE