DC Field | Value | Language |
---|---|---|
dc.contributor.author | 오상우 | - |
dc.contributor.author | 서동민 | - |
dc.contributor.author | 안기영 | - |
dc.contributor.author | 김재우 | - |
dc.contributor.author | 이문진 | - |
dc.contributor.author | 전태병 | - |
dc.contributor.author | 서성규 | - |
dc.date.accessioned | 2021-08-03T04:44:46Z | - |
dc.date.available | 2021-08-03T04:44:46Z | - |
dc.date.issued | 2015 | - |
dc.identifier.issn | 2288-0089 | - |
dc.identifier.issn | 2288-081X | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/812 | - |
dc.description.abstract | To evaluate the degree of contamination caused by oil spill accident in the sea, the in-situ sensors which are based on the scientific method are needed in the real site. The sensors which are based on the fluores-cence detection theory can provide the useful data, such as the concentration of oil. However these kinds of sensors commonly are composed of the ultraviolet (UV) light source such as UV mercury lamp, the multiple excitation/emission filters and the optical sensor which is mainly photomultiplier tube (PMT) type. Therefore, the size of the total sensing platform is large not suitable to be handled in the oil spill field and also the total price of it is extremely expensive. To overcome these drawbacks, we designed the fluorime-ter for the oil spill detection which has compact size and cost effectiveness. Before the detail design pro-cess, we conducted the experiments to measure the excitation and emission spectrum of oils using five different kinds of crude oils and three different kinds of processed oils. And the fluorescence spectrometer were used to analyze the excitation and emission spectrum of oil samples. We have compared the spec-trum results and drawn the each common spectrum regions of excitation and emission. In the experi-ments, we can see that the average gap between maximum excitation and emission peak wavelengths is near 50 nm for the every case. In the experiment which were fixed by the excitation wavelength of 365 nm and 405 nm, we can find out that the intensity of emission was weaker than that of 280 nm and 325 nm. So, if the light sources having the wavelength of 365 nm or 405 nm are used in the design process of fluorimeter, the optical sensor needs to have the sensitivity which can cover the weak light intensity. Through the results which were derived by the experiment, we can define the important factors which can be useful to select the effective wavelengths of light source, photo detector and filters. | - |
dc.format.extent | 6 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 한국해양환경·에너지학회 | - |
dc.title | 형광 광도계 설계인자 도출을 위한 기름의 형광 스펙트럼 분석 | - |
dc.title.alternative | Oil Fluorescence Spectrum Analysis for the Design of Fluorime-ter | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 한국해양환경?에너지학회지, v.18, no.4, pp 304 - 309 | - |
dc.citation.title | 한국해양환경?에너지학회지 | - |
dc.citation.volume | 18 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 304 | - |
dc.citation.endPage | 309 | - |
dc.identifier.kciid | ART002050238 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | 유출유 탐지 | - |
dc.subject.keywordAuthor | 현장탐지 센서 | - |
dc.subject.keywordAuthor | 형광 광도계 | - |
dc.subject.keywordAuthor | 형광 스펙트럼 | - |
dc.subject.keywordAuthor | 형광 분석법 | - |
dc.subject.keywordAuthor | Oil Spill Detection | - |
dc.subject.keywordAuthor | In-situ Sensor | - |
dc.subject.keywordAuthor | Fluorimeter | - |
dc.subject.keywordAuthor | Fluorescence Spectrum | - |
dc.subject.keywordAuthor | Fluorescence Spectroscopy | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.