Performance characteristics of a high-efficiency R717 OTEC power cycle
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 윤정인 | - |
dc.contributor.author | 손창효 | - |
dc.contributor.author | 백승문 | - |
dc.contributor.author | 예병효 | - |
dc.contributor.author | 김현주 | - |
dc.contributor.author | 이호생 | - |
dc.date.accessioned | 2023-12-22T07:31:50Z | - |
dc.date.available | 2023-12-22T07:31:50Z | - |
dc.date.issued | 2014-11-14 | - |
dc.identifier.issn | 1359-4311 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/8034 | - |
dc.description.abstract | This paper proposes a high-efficiency R717 Ocean Thermal Energy Conversion (OTEC) power cycle with an expansion valve and a cooler. To provide the basic design data for the operating variables of this highefficiency R717 OTEC power cycle, the cycle performance was analyzed in terms of the evaporation heat capacity, condensation heat capacity, total work and efficiency using the HYSYS program. The operating variables considered in this study included the high-stage turbine outlet pressure, the expansion valve outlet pressure, the turbine efficiency, the pressure drop of the evaporator and the cooler outlet vapor quality of the R717 OTEC power cycle. The main results can be summarized as follows. The highefficiency R717 OTEC power cycle was most affected by the turbine efficiency and the cooler outlet vapor quality. Therefore, these effects must be considered when the R717 OTEC power cycle is designed. Furthermore, the actual application of the proposed OTEC power cycle requires the development of a highly efficient turbine, the optimal control of the cooler outlet vapor quality and the optimization of the system. The efficiency of the proposed OTEC system is compared with that of Uehara and Kalina one. The efficiency of Uehara, Kalina and proposed OTEC system is 2.379, 2.361 and 2.401, respectively. This OTEC system is the highest efficiency among other systems.he cycle performance was analyzed in terms of the evaporation heat capacity, condensation heat capacity, total work and efficiency using the HYSYS program. The operating variables considered in this study included the high-stage turbine outlet pressure, the expansion valve outlet pressure, the turbine efficiency, the pressure drop of the evaporator and the cooler outlet vapor quality of the R717 OTEC power cycle. The main results can be summarized as follows. The highefficiency R717 OTEC power cycle was most affected by the turbine efficiency and the cooler outlet vapor quality. Therefore, these effects must be considered when the R717 OTEC power cycle is designed. Furthermore, the actual application of the proposed OTEC power cycle requires the development of a highly efficient turbine, the optimal control of the cooler outlet vapor quality and the optimization of the system. The efficiency of the proposed OTEC system is compared with that of Uehara and Kalina one. The efficiency of Uehara, Kalina and proposed OTEC system is 2.379, 2.361 and 2.401, respectively. This OTEC system is the highest efficiency among other systems. | - |
dc.format.extent | 5 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Elsevier | - |
dc.title | Performance characteristics of a high-efficiency R717 OTEC power cycle | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.bibliographicCitation | APPLIED THERMAL ENGINEERING, v.72, no.0, pp 304 - 308 | - |
dc.citation.title | APPLIED THERMAL ENGINEERING | - |
dc.citation.volume | 72 | - |
dc.citation.number | 0 | - |
dc.citation.startPage | 304 | - |
dc.citation.endPage | 308 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | R717 (ammonia) | - |
dc.subject.keywordAuthor | OTEC power cycle | - |
dc.subject.keywordAuthor | Expansion valve | - |
dc.subject.keywordAuthor | Cooler | - |
dc.subject.keywordAuthor | Performance analysis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.