증기 액 이젝터를 적용한 해양온도차발전 시스템의 성능 특성
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 윤정인 | - |
dc.contributor.author | 손창효 | - |
dc.contributor.author | 김현욱 | - |
dc.contributor.author | 하수정 | - |
dc.contributor.author | 이호생 | - |
dc.contributor.author | 김현주 | - |
dc.date.accessioned | 2023-12-22T07:31:42Z | - |
dc.date.available | 2023-12-22T07:31:42Z | - |
dc.date.issued | 2014-12-30 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/8006 | - |
dc.description.abstract | In this paper, the performance analysis of condensation and evaporation capacity, turbine work and efficiency of the OTEC power system using vapor-liquid Ejector is presented to offer the basic design data for the operating parameters of the system. The working fluid used in this system is CO2. The perating parameters considered in this study include the vapor quality at heat exchanger outlet, pressure ratio of ejector and inlet pressure of low turbine, mass flow ratio of separator at condenser outlet. The main results were summarized as follows. The efficiency of the OTEC power cycle has an enormous effect on the mass flow ratio of separator at condenser outlet. With a thorough grasp of these effects, it is possible to design the OTEC power cycle proposed in this study.he system. The working fluid used in this system is CO2. The perating parameters considered in this study include the vapor quality at heat exchanger outlet, pressure ratio of ejector and inlet pressure of low turbine, mass flow ratio of separator at condenser outlet. The main results were summarized as follows. The efficiency of the OTEC power cycle has an enormous effect on the mass flow ratio of separator at condenser outlet. With a thorough grasp of these effects, it is possible to design the OTEC power cycle proposed in this study. | - |
dc.format.extent | 6 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 한국동력기계공학회지 | - |
dc.title | 증기 액 이젝터를 적용한 해양온도차발전 시스템의 성능 특성 | - |
dc.title.alternative | Performance Characteristics of OTEC(Ocean Thermal Energy Conversion) Power Cycle with Vapor-Liquid Ejector | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 한국동력기계공학회지, v.18, no.5, pp 88 - 93 | - |
dc.citation.title | 한국동력기계공학회지 | - |
dc.citation.volume | 18 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 88 | - |
dc.citation.endPage | 93 | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | Efficiency | - |
dc.subject.keywordAuthor | OTEC | - |
dc.subject.keywordAuthor | Ejector | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.