열전달 촉진관에서 HFC32/HFC152a 혼합냉매의 외부 응축열전달계수

Full metadata record
DC Field Value Language
dc.contributor.author이요한-
dc.contributor.author강동규-
dc.contributor.author김현주-
dc.contributor.author이호생-
dc.contributor.author정동수-
dc.date.accessioned2023-12-22T07:31:27Z-
dc.date.available2023-12-22T07:31:27Z-
dc.date.issued2014-12-30-
dc.identifier.urihttps://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/7962-
dc.description.abstractIn this study, external condensation heat transfer coefficients (HTCs) of two non-azeotropic refrigerant mixtures of HFC32/HFC152a at various compositions were measured on both 26 fpi low-fin and Turbo-C enhanced tubes, of 19.0 mm outside diameter. All data were taken at the vapor temperature of 39℃, with a wall subcooling of 3∼8 K. Test results showed that the HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by mass fraction weighting of the pure component HTCs. Also, the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased, as the wall subcooling increased, which was due to the sudden break-up of the vapor diffusion film with an increase in wall subcooling. Finally, the heat transfer enhancement ratios for mixtures were found to be much lower, than those of pure fluids.iameter. All data were taken at the vapor temperature of 39℃, with a wall subcooling of 3∼8 K. Test results showed that the HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by mass fraction weighting of the pure component HTCs. Also, the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased, as the wall subcooling increased, which was due to the sudden break-up of the vapor diffusion film with an increase in wall subcooling. Finally, the heat transfer enhancement ratios for mixtures were found to be much lower, than those of pure fluids.-
dc.format.extent7-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한설비공학회-
dc.title열전달 촉진관에서 HFC32/HFC152a 혼합냉매의 외부 응축열전달계수-
dc.title.alternativeExternal Condensation Heat Transfer Coefficients of HFC32/HFC152a Mixtures on Enhanced Tubes-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation대한설비공학회 논문집, v.26, no.7, pp 315 - 321-
dc.citation.title대한설비공학회 논문집-
dc.citation.volume26-
dc.citation.number7-
dc.citation.startPage315-
dc.citation.endPage321-
dc.description.isOpenAccessN-
dc.subject.keywordAuthorCondensation heat transfer-
dc.subject.keywordAuthorRefrigerant mixture-
dc.subject.keywordAuthorHeat transfer coefficient-
Files in This Item
There are no files associated with this item.
Appears in
Collections
친환경해양개발연구본부 > 해수에너지연구센터 > Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hyeon Ju photo

Kim, Hyeon Ju
친환경해양개발연구본부 (해수에너지연구센터)
Read more

Altmetrics

Total Views & Downloads

BROWSE