열전달 촉진관에서 HFC32/HFC152a 혼합냉매의 외부 응축열전달계수
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이요한 | - |
dc.contributor.author | 강동규 | - |
dc.contributor.author | 김현주 | - |
dc.contributor.author | 이호생 | - |
dc.contributor.author | 정동수 | - |
dc.date.accessioned | 2023-12-22T07:31:27Z | - |
dc.date.available | 2023-12-22T07:31:27Z | - |
dc.date.issued | 2014-12-30 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/7962 | - |
dc.description.abstract | In this study, external condensation heat transfer coefficients (HTCs) of two non-azeotropic refrigerant mixtures of HFC32/HFC152a at various compositions were measured on both 26 fpi low-fin and Turbo-C enhanced tubes, of 19.0 mm outside diameter. All data were taken at the vapor temperature of 39℃, with a wall subcooling of 3∼8 K. Test results showed that the HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by mass fraction weighting of the pure component HTCs. Also, the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased, as the wall subcooling increased, which was due to the sudden break-up of the vapor diffusion film with an increase in wall subcooling. Finally, the heat transfer enhancement ratios for mixtures were found to be much lower, than those of pure fluids.iameter. All data were taken at the vapor temperature of 39℃, with a wall subcooling of 3∼8 K. Test results showed that the HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by mass fraction weighting of the pure component HTCs. Also, the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased, as the wall subcooling increased, which was due to the sudden break-up of the vapor diffusion film with an increase in wall subcooling. Finally, the heat transfer enhancement ratios for mixtures were found to be much lower, than those of pure fluids. | - |
dc.format.extent | 7 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 대한설비공학회 | - |
dc.title | 열전달 촉진관에서 HFC32/HFC152a 혼합냉매의 외부 응축열전달계수 | - |
dc.title.alternative | External Condensation Heat Transfer Coefficients of HFC32/HFC152a Mixtures on Enhanced Tubes | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 대한설비공학회 논문집, v.26, no.7, pp 315 - 321 | - |
dc.citation.title | 대한설비공학회 논문집 | - |
dc.citation.volume | 26 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 315 | - |
dc.citation.endPage | 321 | - |
dc.description.isOpenAccess | N | - |
dc.subject.keywordAuthor | Condensation heat transfer | - |
dc.subject.keywordAuthor | Refrigerant mixture | - |
dc.subject.keywordAuthor | Heat transfer coefficient | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.