대형캐비테이션터널(LCT) 실물 구동펌프 성능시운전Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT)
- Other Titles
- Performance Trial-Test of the Full-Scale Driving Pump for the Large Cavitation Tunnel(LCT)
- Authors
- 안종우; 김건도; 김기섭; 박영하
- Issue Date
- 2015
- Publisher
- 대한조선학회
- Keywords
- Performance trial-test; Driving pump design; Large cavitation tunnel; Full-scale pump; 성능 시운전; 구동펌프 설계; 대형캐비테이션터널; 실물 펌프
- Citation
- 대한조선학회 논문집, v.52, no.6, pp 428 - 434
- Pages
- 7
- Journal Title
- 대한조선학회 논문집
- Volume
- 52
- Number
- 6
- Start Page
- 428
- End Page
- 434
- URI
- https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/792
- ISSN
- 1225-1143
- Abstract
- The objective of the present study is to analyze the results of the trial-test for the full-scale driving pump, which is arranged in the LCT (Large Cavitation Tunnel). Firstly, the reasons of selecting the final design pump are introduced in terms of the performance analysis in model tests. The trial-test items for the full-scale driving pump are measurements of output current/voltage at the inverter of the main motor and the flow velocity in the LCT test section. The test results show the increase in flow rate of about 10.7% and the decrease in pump head of about 26%, compared with those of final design-pump specification. The motor power has the margin of about 22%. The performance analysis for the full-scale pump is conducted using the commercial code (CFX-10). The delivered power calculated with CFX-10 shows good agreement with that extracted from the full-scale pump test. It is found that CFX-10 is useful to analyze a full-scale pump.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 선박연구본부 > Naval Ship Engineering Research Center > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.