dc.description.abstract | In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system applied various refrigerants is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporation temperature, condensing temperature, mass flow rate ration into inter-cooler, effectiveness of internal heat exchanger. The main results were summarized as follows : The COP of two-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling, mass flow rate ration of inter-cooler, evaporation temperature, but decreases with the increasing condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and 1-stage expansion using substitute refrigerant have an effect on COP of this system. The COP of alternative refrigerants was higher than the COP of R22 in this study, although the COP of some mixed refrigerants were lower than COP of R22. | - |
dc.format.extent | 7 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 한국동력기계공학회 | - |
dc.title | 다양한 냉매를 적용한 내부열교환기 부착 2단 압축 냉동시스템의 성능 분석 | - |
dc.title.alternative | Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.doi | 10.9726/kspse.2015.19.6.082 | - |
dc.identifier.bibliographicCitation | 동력시스템공학회지, v.19, no.6, pp 82 - 88 | - |
dc.citation.title | 동력시스템공학회지 | - |
dc.citation.volume | 19 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 82 | - |
dc.citation.endPage | 88 | - |
dc.identifier.kciid | ART002065573 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Two-stage compression and one-stage expansion refrigeration system | - |
dc.subject.keywordAuthor | Alternative refrigerant | - |
dc.subject.keywordAuthor | Internal heat exchanger | - |
dc.subject.keywordAuthor | COP | - |
dc.subject.keywordAuthor | Mass flow-rate | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.