Detailed Information

Cited 1 time in webofscience Cited 1 time in scopus
Metadata Downloads

Eddy current loss in double-sided cored slotless type permanent magnet linear synchronous generator using analytical method

Authors
Jang, Gang-HyeonKoo, Min-MoSeo, Sung-WonHong, KeyyongChoi, Jang-Young
Issue Date
5월-2017
Publisher
AMER INST PHYSICS
Keywords
Eddy current loss; Double-sided cored slotless type; Permanent magnet; Linear generator; Analytical method
Citation
AIP ADVANCES, v.7, no.5
Journal Title
AIP ADVANCES
Volume
7
Number
5
URI
https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/575
DOI
10.1063/1.4973435
ISSN
2158-3226
Abstract
This paper describes the eddy current loss analysis of a double-sided cored slotless-type permanent magnet linear synchronous generator using the space harmonic method. To calculate the eddy current, an analytical solution was derived by applying the Maxwell equation, magnetic vector potential, and Faraday's law in a two-dimensional (2-D) Cartesian coordinate system. Based on the armature reaction field distribution produced by the armature winding current, we obtained an analytical solution for the eddy current density distribution. Then, an analytical solution for eddy current loss induced in a permanent magnet (PM) was derived using the equivalent electrical resistance calculated from the PM's volume and eddy current density distribution solution. Finally, the resulting current was determined based on analysis of the eddy current loss. The analytical results produced using this application of the space harmonic method were validated extensively through comparison with finite element method results. (C) 2016 Author(s).
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads

BROWSE