다관절 해저로봇 "CR200의 수중 링크-관절 시스템 설계
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 강한구 | - |
dc.contributor.author | 심형원 | - |
dc.contributor.author | 전봉환 | - |
dc.contributor.author | 이판묵 | - |
dc.date.accessioned | 2021-12-08T18:40:31Z | - |
dc.date.available | 2021-12-08T18:40:31Z | - |
dc.date.issued | 20120521 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/5323 | - |
dc.description.abstract | This paper presents the design of an underwater link-joint system for developing of a 200m class six-legged subsea robot. The design includes a process with concept establishment, specific design for joint capability and mechanical drawing. First deals with the definition of degree of freedom which is the link-joint system. Second is the design with calculation of velocity and torque of joints, selection of motor, reduction gears, sensors, and driver. Final is the mechanical design of configuration of the underwater link-joint system. Especially, the specific design is based on simple static and dynamic force analysis considering the performance requirement. And the mechanical design includes the thickness calculation of joint pressure vessel to satisfy the required pressure-resistant capability, and shows the detailed design using 2D and 3D computer aided design(CAD) software. This paper describes the whole design process of the underwater link- joint system for manufacturing the leg of CR200.ing. First deals with the definition of degree of freedom which is the link-joint system. Second is the design with calculation of velocity and torque of joints, selection of motor, reduction gears, sensors, and driver. Final is the mechanical design of configuration of the underwater link-joint system. Especially, the specific design is based on simple static and dynamic force analysis considering the performance requirement. And the mechanical design includes the thickness calculation of joint pressure vessel to satisfy the required pressure-resistant capability, and shows the detailed design using 2D and 3D computer aided design(CAD) software. This paper describes the whole design process of the underwater link- joint system for manufacturing the leg of CR200. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.title | 다관절 해저로봇 &quotCR200의 수중 링크-관절 시스템 설계 | - |
dc.title.alternative | Design of the Underwater Link-Joint System for the Multi-Legged Underwater Robot &quotCR200 | - |
dc.type | Conference | - |
dc.citation.title | Oceans 2012 | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 6 | - |
dc.citation.conferenceName | Oceans 2012 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.