Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring DeviceDevelopment of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

Other Titles
Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device
Authors
Jeonghee LeeIk-Hyun KimJong-Won ParkYong-Kon Lim문명국Sangheon LeeChang Hwy Lim
Issue Date
2018
Publisher
대한방사선방어학회
Keywords
Container scanner; High energy X-ray; X-ray spatial dose distribution; Diode array
Citation
방사선방어학회지, v.43, no.3, pp 97 - 106
Pages
10
Journal Title
방사선방어학회지
Volume
43
Number
3
Start Page
97
End Page
106
URI
https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/520
DOI
10.14407/jrpr.2018.43.3.97
ISSN
2508-1888
2466-2461
Abstract
Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jong Won photo

Park, Jong Won
해양공공디지털연구본부
Read more

Altmetrics

Total Views & Downloads

BROWSE