비대칭 날개를 사용한 OWC 파력발전용 임펄스터빈의 성능예측에 대한 수치적인 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김길원 | - |
dc.contributor.author | 홍기용 | - |
dc.contributor.author | 현범수 | - |
dc.contributor.author | 류진 | - |
dc.date.accessioned | 2021-12-08T17:40:24Z | - |
dc.date.available | 2021-12-08T17:40:24Z | - |
dc.date.issued | 20130523 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/4995 | - |
dc.description.abstract | The bi-directional air flow isolated in the air chamber drive the air turbine rotating by oscillating water column. Because of the compressibility of air, the air flow rates are different comparing the exhausting and inhaling process. The unsymmetric bladed impulse turbine are suggested to improve the power of converting system using the difference of airflow rate. The optimum unsymmetric ratio and angle of guide-vane have investigated using numerical method.nsymmetric bladed impulse turbine are suggested to improve the power of converting system using the difference of airflow rate. The optimum unsymmetric ratio and angle of guide-vane have investigated using numerical method. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.title | 비대칭 날개를 사용한 OWC 파력발전용 임펄스터빈의 성능예측에 대한 수치적인 연구 | - |
dc.title.alternative | Numerical Study on Performance of Unsymmetric Bladed Impulse Turbine for OWC Wave Energy Converter | - |
dc.type | Conference | - |
dc.citation.title | 한국해양환경 에너지학회 춘계학술대회 | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 2934 | - |
dc.citation.endPage | 2940 | - |
dc.citation.conferenceName | 한국해양환경 에너지학회 춘계학술대회 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.