온열원 변화에 따른 20kW 해수온도차발전 플랜트 운전
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이호생 | - |
dc.contributor.author | 차상원 | - |
dc.contributor.author | 윤정인 | - |
dc.contributor.author | 김현주 | - |
dc.date.accessioned | 2021-12-08T14:41:13Z | - |
dc.date.available | 2021-12-08T14:41:13Z | - |
dc.date.issued | 20141204 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/4361 | - |
dc.description.abstract | Ocean Thermal Energy Conversion(OTEC) is a method that utilizes the natural temperature gradient that exists in tropical ocean between warm surface water and the deep sea water to generate electricity. When the temperature difference between surface seawater and deep seawater is over 20℃, the system can be run with much better efficiency. Researches for the cases of low temperature differences are also ongoing. In this paper, to perform an experiment on the 20kW OTEC, a closed OTEC cycle was designed and fabricated. R32 was used as the working fluid, and the temperature of the heat source and heat sink were 26℃ and 5℃ respectively. A semi-welded-type heat exchanger was used as the evaporator and condenser, and the OTEC cycle was designed for a gross power of 20kW. R32-OTEC was installed in Seawater Utilization Plant Research Center in Gosung-gun, Gangwon-do.n surface seawater and deep seawater is over 20℃, the system can be run with much better efficiency. Researches for the cases of low temperature differences are also ongoing. In this paper, to perform an experiment on the 20kW OTEC, a closed OTEC cycle was designed and fabricated. R32 was used as the working fluid, and the temperature of the heat source and heat sink were 26℃ and 5℃ respectively. A semi-welded-type heat exchanger was used as the evaporator and condenser, and the OTEC cycle was designed for a gross power of 20kW. R32-OTEC was installed in Seawater Utilization Plant Research Center in Gosung-gun, Gangwon-do. | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.title | 온열원 변화에 따른 20kW 해수온도차발전 플랜트 운전 | - |
dc.title.alternative | Operation of the 20kW OTEC Plant according to changed heat source | - |
dc.type | Conference | - |
dc.citation.title | 한국동력기계공학회 추계학술대회 | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 25 | - |
dc.citation.endPage | 26 | - |
dc.citation.conferenceName | 한국동력기계공학회 추계학술대회 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.