해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant
- Other Titles
- Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant
- Authors
- 박창수; 성기영; 한성종
- Issue Date
- 2019
- Publisher
- 한국산업융합학회
- Keywords
- Pickling; Oil Flushing; National Aerospace Standard 1638; International Organization for Standard 4406
- Citation
- 한국산업융합학회논문집, v.22, no.6, pp 797 - 805
- Pages
- 9
- Journal Title
- 한국산업융합학회논문집
- Volume
- 22
- Number
- 6
- Start Page
- 797
- End Page
- 805
- URI
- https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/420
- DOI
- 10.21289/KSIC.2019.22.6.797
- ISSN
- 1226-833x
- Abstract
- An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - ETC > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.