전기분해방식 선박평형수 처리장치에서 발생하는 활성물질의 최대 허용 농도에 관한 고찰
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김은찬 | - |
dc.contributor.author | 오정환 | - |
dc.contributor.author | 이승국 | - |
dc.date.accessioned | 2021-12-08T13:41:02Z | - |
dc.date.available | 2021-12-08T13:41:02Z | - |
dc.date.issued | 20151112 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/4027 | - |
dc.description.abstract | The International Convention for the Control and Management of Ships Ballast Water and Sediments was adopted by IMO (International Maritime Organization) on 13 February 2004. Fifty-seven ballast water management systems were granted basic approval of active substance by IMO, among which thirty-seven systems were granted final approval. This paper studies the maximum allowable dosage of active substances produced by ballast water management system using electrolysis which is approved management system by IMO. The allowable dosage of active substances by electrolysis system is proposed by TRO (Total Residual Oxidant). However, between various management systems TRO concentration of maximum allowable dosage showed large differences, ranging from 1 to 15 ppm, depending on the management systems. The discrepancies of maximum allowable dosage among the management systems may be whether a filter is used or not, the difference in the specifications of electrolysis module, the kind of tested organisms, the number of individual organisms, and the difference of water quality, etc. approval of active substance by IMO, among which thirty-seven systems were granted final approval. This paper studies the maximum allowable dosage of active substances produced by ballast water management system using electrolysis which is approved management system by IMO. The allowable dosage of active substances by electrolysis system is proposed by TRO (Total Residual Oxidant). However, between various management systems TRO concentration of maximum allowable dosage showed large differences, ranging from 1 to 15 ppm, depending on the management systems. The discrepancies of maximum allowable dosage among the management systems may be whether a filter is used or not, the difference in the specifications of electrolysis module, the kind of tested organisms, the number of individual organisms, and the difference of water quality, etc. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.title | 전기분해방식 선박평형수 처리장치에서 발생하는 활성물질의 최대 허용 농도에 관한 고찰 | - |
dc.title.alternative | Consideration on the Maximum Allowable Dosage of Active Substances Produced by Ballast Water Management System Using Electrolysis | - |
dc.type | Conference | - |
dc.identifier.doi | ISSN 2289-067X | - |
dc.citation.title | International conference on Advanced Intelligent Maritime Safety and Technology 2015 | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 113 | - |
dc.citation.endPage | 119 | - |
dc.citation.conferenceName | International conference on Advanced Intelligent Maritime Safety and Technology 2015 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.