100KW급 고온도차발전플랜트의 신소재 열교환기 적용에 의한 성능 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이호생 | - |
dc.contributor.author | 임승택 | - |
dc.contributor.author | 문정현 | - |
dc.contributor.author | 김현주 | - |
dc.date.accessioned | 2021-12-08T13:40:17Z | - |
dc.date.available | 2021-12-08T13:40:17Z | - |
dc.date.issued | 20160524 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/3827 | - |
dc.description.abstract | For using high temperature difference between over 75℃ as heat source and 5℃ as heat sink, 100kW high temperature ocean thermal energy conversion(H-OTEC) was designed and manufactured. We've researched using higher temperature heat source from waste heat and deep sea water instead of traditional heat sink. Such an enough temperature difference between heat source and heat sink shows the possibility of the efficient generation and that plays an important role in supplying renewable energy for distributed local demands. In this paper, to perform an experiment on the 100kW H-OTEC plant, an organic rankine cycle was designed and fabricated. R245fa was used as the working fluid, and the temperature of the heatsource and heat sink were 75℃ and 5℃ respectively. The heat exchangers for evaporator and condenser were manufactured by Titanium and Oxynitride coating(SPCC) plates resisting to sea water corrosion, and the hybrid ocean thermal energy conversion cycle was designed for a gross power of 100kW. The H-OTEC plant was installed in Seawater Utilization Plant Research Center at Gosung-gun, Gangwon-do. The H-OTEC plants was tested to analyze the operation performance and compare the efficiency of both H-OTEC plants with condensers of Titanium and Oxynitriding steel heat exchangers. Based on the procedure of design, fabrication, operation, and demonstration record, both 100kW H-OTEC plants can be considered to be appl | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.title | 100KW급 고온도차발전플랜트의 신소재 열교환기 적용에 의한 성능 평가 | - |
dc.title.alternative | Performance Test of 100kW H-OTEC Plant Using Oxynitride Steel Condenser | - |
dc.type | Conference | - |
dc.citation.title | 한국신재생에너지학회 춘계학술대회 | - |
dc.citation.volume | 1 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 78 | - |
dc.citation.endPage | 78 | - |
dc.citation.conferenceName | 한국신재생에너지학회 춘계학술대회 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.