Development of Spatial Dose Distribution measuring system of X-ray Beamline in Cargo container scanner using MV energy x-ray

Full metadata record
DC Field Value Language
dc.contributor.author임창휘-
dc.contributor.author박종원-
dc.contributor.author이정희-
dc.contributor.author김익현-
dc.contributor.author임용곤-
dc.contributor.author문명국-
dc.contributor.author이상헌-
dc.date.accessioned2021-12-08T11:40:34Z-
dc.date.available2021-12-08T11:40:34Z-
dc.date.issued20171023-
dc.identifier.urihttps://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/3329-
dc.description.abstractA cargo container scanner using X-ray generally inspects the interior of the container non-destructively using MV X-ray. Scanning system should be designed with a structure to minimize the leakage of X-ray dose. To do this, precise control of the incident direction and distribution of X-ray beam has to be performed. In order perform the control, precise alignment of the X-ray and image detector should be performed and accurate collimation of the X-ray beam should be performed. And the X-ray beam distribution by position must be accurately measured. In order to measure the x-ray spatial dose distribution, methods using ion chambers, diodes, plastic scintillators, etc. can be used. Among these methods, the method using diode is difficult to measure the dose accurately compared to the ion chamber, but it has a merit that the size of the pixel can be made relatively small, the manufacturing cost is low, and the maintenance is simple. For this reason, a dose measuring device using a diode is widely used for measuring the dose. So, we have developed the spatial dose distribution measuring system to measure the spatial dose distribution of cargo container scanner. The experimental evaluation of the developed X-ray spatial dose distribution measuring device was carried out in the cargo container scanner test bed developed by KRISO (Korea Research Institute of Ship and Ocean Engineering). Experiments were carried out on the-
dc.language영어-
dc.language.isoENG-
dc.titleDevelopment of Spatial Dose Distribution measuring system of X-ray Beamline in Cargo container scanner using MV energy x-ray-
dc.title.alternativeDevelopment of Spatial Dose Distribution measuring system of X-ray Beamline in Cargo container scanner using MV energy x-ray-
dc.typeConference-
dc.identifier.doi0-
dc.citation.titleIEEE NSS-MIC 2017-
dc.citation.volume0-
dc.citation.number0-
dc.citation.startPage0-
dc.citation.endPage0-
dc.citation.conferenceNameIEEE NSS-MIC 2017-
dc.citation.conferencePlace미국-
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 2. Conference Papers

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jong Won photo

Park, Jong Won
해양공공디지털연구본부
Read more

Altmetrics

Total Views & Downloads

BROWSE