Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Power Performance Analysis According to the Configuration and Load Control Algorithm of Power Take-Off System for Oscillating Water Column Type Wave Energy Converters

Authors
Chan, RohKim, Kil-WonPark, Ji-YongPark, Se-WanKim, Kyong-HwanKwak, Sang-Shin
Issue Date
12월-2020
Publisher
MDPI
Keywords
oscillating water column; wave energy converter; turbine efficiency; power converter topology; load control; maximum power point control; torque control coefficient; power performance
Citation
ENERGIES, v.13, no.23
Journal Title
ENERGIES
Volume
13
Number
23
URI
https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/206
DOI
10.3390/en13236415
ISSN
1996-1073
1996-1073
Abstract
A power take-off (PTO) system for an oscillating water column (OWC) wave energy converter comprises a turbine-generator-power converter. In this study, only the topologies of the power converter that affect the load control algorithm are compared. A power converter for renewable energy is composed of a diode-dc/dc converter and a pulse-width modulation (PWM) converter operating at small and large capacities, respectively. However, selecting a power converter according to the capacity based on the characteristics of the wave energy converter, in which the input energy is highly fluctuating, can significantly reduce the power performance. Thus, to verify load control characteristics according to the topology of the power converter, the turbine-generator-power converter was incorporated in the modeling, and the power performance based on the power converter topology under various wave conditions was analyzed. Further, torque control to obtain the maximum power among load control algorithms was applied under irregular wave conditions, and the power performance and PTO system characteristics according to the torque coefficient were analyzed. The results of this study suggested an increase in the torque coefficient of the maximum power control for the operational stability of the OWC-WEC, and it was confirmed that the RPM characteristics of the PTO system were reduced.
Files in This Item
There are no files associated with this item.
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Kyong-Hwan photo

Kim, Kyong-Hwan
친환경해양개발연구본부
Read more

Altmetrics

Total Views & Downloads

BROWSE