Waterjet Intake 유도관 성능시험법 개발Development of Performance Test System for waterjet Intake-Diffuser
- Other Titles
- Development of Performance Test System for waterjet Intake-Diffuser
- Authors
- 안종우; 박영하; 김기섭; 김경열
- Issue Date
- 28-2월-2003
- Publisher
- 한국해양연구원
- Keywords
- Waterjet propulsion; Intake-diffuser; 5-hole pitot tube; 손실해석; intake lip cavitation
- Citation
- 선박해양기술, v.35, no.1, pp 161 - 167
- Pages
- 7
- Journal Title
- 선박해양기술
- Volume
- 35
- Number
- 1
- Start Page
- 161
- End Page
- 167
- URI
- https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/1811
- Abstract
- In order to develope the intake-diffuser with good performance for the waterjet propulsion system, new experimental device was designed and manufactured. The experimental device is installed on the test section of the KRISO cavitation tunnel. The efficiency of the intake-diffuser is calculated using the measurement result of 1-hole and 5-hole pitot tubes. The calibration of the 5-hole pitot tubes is conducted at the cavitation tunnel. The cavitation inception occurs at the intake lip, and the occurrence position depends on IVR (Inlet Velocity Ratio) condition. The present test device will be applied sufficiently for the development of the design and perfomance analysis methods.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - 선박연구본부 > Naval Ship Engineering Research Center > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.