Aliivibrio fischeri의 발광저해율을 이용한 해양산업시설 배출 위험·유해물질(HNS) 생태독성 평가 및 실시간 모니터링 적용성 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 최진수 | - |
dc.contributor.author | 이경진 | - |
dc.contributor.author | 이문진 | - |
dc.contributor.author | 김용명 | - |
dc.contributor.author | 최훈 | - |
dc.contributor.author | 이동권 | - |
dc.date.accessioned | 2025-01-08T06:30:40Z | - |
dc.date.available | 2025-01-08T06:30:40Z | - |
dc.date.issued | 2024-08 | - |
dc.identifier.issn | 1229-8425 | - |
dc.identifier.issn | 2635-7437 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/10667 | - |
dc.description.abstract | Ecotoxicity assessment was conducted to develop a rapid monitoring system for hazardous and noxious substances (HNS) in marine environments. A total of 24 individual substances (i.e., 10 types of volatile organic compounds (VOCs), 6 types of heavy metals, and 8 other water pollutants) were evaluated with the Microtox bioassay technique adopting Aliivibrio fischeri based on exposure times of 5, 15, and 30 minutes. The EC50 (30 min) for VOCs was measured across a diverse concentration range of 5.26 to 70,710.70 mg·L-1. For heavy metals, the EC50 (30 min) was measured in the range of 0.08 to 53.59 mg·L-1. For water pollutants, the EC50 was also determined in the range of 13.34 to 615.57 mg·L-1. In all cases, it was observed that as the contact time increased, the EC50 decreased, which indicated higher sensitivity in toxicity detection. Except for a few cases, a contact time of 5 minutes was sufficient to ensure satisfactory sensitivity in toxicity detection. Further research under various conditions, interference factors, and mixed toxicity could provide foundational data for establishing a real-time HNS monitoring system. | - |
dc.format.extent | 10 | - |
dc.language | 한국어 | - |
dc.language.iso | KOR | - |
dc.publisher | 한국환경기술학회 | - |
dc.title | Aliivibrio fischeri의 발광저해율을 이용한 해양산업시설 배출 위험·유해물질(HNS) 생태독성 평가 및 실시간 모니터링 적용성 연구 | - |
dc.title.alternative | Study on the Ecotoxicity Assessment and Real-Time Monitoring Applicability of Hazardous and Noxious Substances (HNS) Discharged from Marine Industrial Facilities Using the Bioluminescence Inhibition Rate of Aliivibrio fischeri | - |
dc.type | Article | - |
dc.publisher.location | 대한민국 | - |
dc.identifier.bibliographicCitation | 한국환경기술학회지, v.25, no.4, pp 244 - 253 | - |
dc.citation.title | 한국환경기술학회지 | - |
dc.citation.volume | 25 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 244 | - |
dc.citation.endPage | 253 | - |
dc.identifier.kciid | ART003115554 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Ecotoxicity assessment | - |
dc.subject.keywordAuthor | HNS monitoring | - |
dc.subject.keywordAuthor | Aliivibrio fischeri | - |
dc.subject.keywordAuthor | Heavy metals | - |
dc.subject.keywordAuthor | VOCs | - |
dc.subject.keywordAuthor | Organic matters | - |
dc.subject.keywordAuthor | . | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.