Coupled CFD modeling and thermal analysis of multi-layered insulation structures in liquid hydrogen storage tanks for various vapor-cooled shields
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zhu, Xian You | - |
dc.contributor.author | Lee, Jung Hee | - |
dc.contributor.author | Kim, Kyong-Hwan | - |
dc.contributor.author | Lim, Chang-Hyuck | - |
dc.contributor.author | Lee, Seong Hyuk | - |
dc.date.accessioned | 2025-01-08T06:30:23Z | - |
dc.date.available | 2025-01-08T06:30:23Z | - |
dc.date.issued | 2024-11 | - |
dc.identifier.issn | 2214-157X | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/10633 | - |
dc.description.abstract | The present study aims to propose a coupled numerical model for analyzing the influence of the configuration of the vapor-cooled shield tubes on insulation performance. The numerical model is developed to calculate the effective thermal conductivity of multi-layer insulation (MLI) and rigorously evaluated. Specifically, the tank evaporation simulation software BoilFAST is manually coupled with the CFD commercial software of ANSYS FLUENT (2020 R2) to accurately determine the mass flow rate and temperature of boil-off gas in a tank, which is then used as inputs for the CFD simulations. This coupling methodology can be used for reliable calculations of boil-off losses for liquid hydrogen and heat transfer inside the MLI structures. Results demonstrate that the estimated effective thermal conductivity agrees with the earlier published data and that increasing the diameter and number of tubes enhances heat exchange between the VCS tubes and MLI structures. Also, the heat flux into the tank is relatively reduced by 32.04 % by increasing the diameter of the tube and 49.14 % by adding the number of tubes. Moreover, the maximum temperature difference of the VCS is estimated to be less than 1 K, indicating nearly uniform distributions of the VCS. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | ELSEVIER | - |
dc.title | Coupled CFD modeling and thermal analysis of multi-layered insulation structures in liquid hydrogen storage tanks for various vapor-cooled shields | - |
dc.type | Article | - |
dc.publisher.location | 네덜란드 | - |
dc.identifier.doi | 10.1016/j.csite.2024.105317 | - |
dc.identifier.scopusid | 2-s2.0-85207600692 | - |
dc.identifier.wosid | 001347373600001 | - |
dc.identifier.bibliographicCitation | CASE STUDIES IN THERMAL ENGINEERING, v.63 | - |
dc.citation.title | CASE STUDIES IN THERMAL ENGINEERING | - |
dc.citation.volume | 63 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Thermodynamics | - |
dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
dc.subject.keywordPlus | CONDUCTIVITY | - |
dc.subject.keywordPlus | OPTIMIZATION | - |
dc.subject.keywordAuthor | Computational fluid dynamics (CFD) | - |
dc.subject.keywordAuthor | Liquid hydrogen storage | - |
dc.subject.keywordAuthor | Thermal insulation performance | - |
dc.subject.keywordAuthor | Vapor-cooled shield (VCS) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.