Minimum Detection Concentration of Hydrogen in Air Depending on Substrate Type and Design of the 3ω Sensor
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oh, Dong-Wook | - |
dc.contributor.author | Kang, Kwangu | - |
dc.contributor.author | Lee, Jung Hee | - |
dc.date.accessioned | 2024-01-11T01:00:05Z | - |
dc.date.available | 2024-01-11T01:00:05Z | - |
dc.date.issued | 2023-11 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.issn | 1424-3210 | - |
dc.identifier.uri | https://www.kriso.re.kr/sciwatch/handle/2021.sw.kriso/10320 | - |
dc.description.abstract | Hydrogen has emerged as a promising carbon-neutral fuel source, spurring research and development efforts to facilitate its widespread adoption. However, the safe handling of hydrogen requires precise leak detection sensors due to its low activation energy and explosive potential. Various detection methods exist, with thermal conductivity measurement being a prominent technique for quantifying hydrogen concentrations. However, challenges remain in achieving high measurement sensitivity at low hydrogen concentrations below 1% for thermal-conductivity-based hydrogen sensors. Recent research explores the 3 omega method's application for measuring hydrogen concentrations in ambient air, offering high spatial and temporal resolutions. This study aims to enhance hydrogen leak detection sensitivity using the 3 omega method by conducting thermal analyses on sensor design variables. Factors including substrate material, type, and sensor geometry significantly impact the measurement sensitivity. Comparative evaluations consider the minimum detectable hydrogen concentration while accounting for the uncertainty of the 3 omega signal. The proposed suspended-type 3 omega sensor is capable of detecting hydrogen leaks in ambient air and provides real-time measurements that are ideal for monitoring hydrogen diffusion. This research serves to bridge the gap between precision and real-time monitoring of hydrogen leak detection, promising significant advancements in the related safety applications. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Multidisciplinary Digital Publishing Institute (MDPI) | - |
dc.title | Minimum Detection Concentration of Hydrogen in Air Depending on Substrate Type and Design of the 3ω Sensor | - |
dc.type | Article | - |
dc.publisher.location | 스위스 | - |
dc.identifier.doi | 10.3390/s23219009 | - |
dc.identifier.bibliographicCitation | Sensors, v.23, no.21 | - |
dc.citation.title | Sensors | - |
dc.citation.volume | 23 | - |
dc.citation.number | 21 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(34103) 대전광역시 유성구 유성대로1312번길 32042-866-3114
COPYRIGHT 2021 BY KOREA RESEARCH INSTITUTE OF SHIPS & OCEAN ENGINEERING. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.